With the rapid development of optical network, there is a need of PON Power Meter to judge the transmission quality of optical link during the opening and maintenance of operators EPON/GPON services.
OFT-1120A is a portable tester specially designed for FTTx/PON passive optical network testing, which can be connected to OLT and ONT so as to realize online synchronous measurement and display of optical signal. It is a helpful assistant for PON network engineer technicians for field testing.
Make an easy evaluation for optical power in any place of whole network from OLT to ONT
l FTTx/PON deployment:during opening phase, measure all PON signal, verify and ensure to meet network standards;
l FTTx/PON maintenance:various transportation problems in daily maintenance, for example, contaminated end face, fiber macro bending and fracture, optical transceivers fault etc.
Dual-port Optical power test
?l 1310nm/1490nm/1550nm optical power test:in the same time test three wavelength signal including 1490nm, 1550nm, 1310nm in PON network
?l 1310nm burst optical power test:1310nm wavelength upstream burst signal testing
General
|
Size
|
146×87×50 (mm)
|
Weight
|
400g
|
Display
|
320 × 240 TFT true color, touch screen
|
Operation mode
|
touch screen and keyboard
|
Optical fiber type
|
SM 9/125um
|
Optical fiber connector
|
2.5mm any standards
|
Interfaces
|
Optical interfaces 2, USB 1, DC power 1
|
Rechargeable lithium battery
|
Charging time
|
4hrs
|
Operation time
|
>50hrs
|
Operation
Environment
|
Operation temperature
|
0℃~+50℃
|
Storage temperature
|
-20℃~+70℃
|
Operation humidity
|
10% ~ 90%
|
Storage humidity
|
5% ~ 95%
|
Resolution
|
0.01dB
|
Data storage space
|
500 records
|
Test Index
|
1310nm Upstream
|
Spectral passband
|
1260nm~1360nm
|
Measurement range
|
-36dBm~+10dBm
|
Max input power
|
+15dBm
|
Isolation (1490/1550nm)
|
>40dB
|
Burst testing
|
Error <1dB
|
Testing - 1490nm Downstream
|
Spectral passband
|
1480nm~1500nm
|
Measurement range
|
-50dBm~+10dBm
|
Max input power
|
+15dBm
|
Isolation (1310nm)
|
>40dB
|
Isolation (1550nm)
|
>35dB
|
Testing - 1550nm Downstream
|
Spectral passband
|
1530nm~1570nm
|
Measurement range
|
-45dBm~+25dBm
|
Max input power
|
+25dBm
|
Isolation(1310nm)
|
>40dB
|
Isolation(1490nm)
|
>35dB
|
Measurement Precision
|
Fixed uncertainty (dB)
|
±0.5
|
PDL(dB)
|
<±0.25
|
Linearity(dB)
|
±0.1
|
Throughput insertion loss(dB)
|
<1.5
|